元器件交易网www.cecb2b.comTemperature ControllerDIN-sized (48 x 48 mm) TemperatureController With Digital SettingCompact, low-cost Temperature ControllerIncorporates proportional adjustment and resetadjustment function.Incorporates a plug-in socket, thus allows toDIN-track and flush mounting.E5C4Ordering Information Temperature ControllersSetting methodIndicationmethodControlmodeOutputModelThermocouple(with sensor burnout detectioncircuit)RelayVoltage (fordriving SSR)PRelayVoltage (fordriving SSR)Note:E5C4-R20KE5C4-Q20KE5C4-R40KE5C4-Q40KE5C4-R20JE5C4-Q20JE5C4-R40JE5C4-Q40JPlatinum resistancethermometerJPt100E5C4-R20PE5C4-Q20PE5C4-R40PE5C4-Q40PDigital settingDigital indicationON/OFFWhen placing an order, specify the standard temperature range and supply voltage in addition to the model number.(e.g., E5C4-R20K0°C to 399°C100/110 VAC) Accessories (Order Separately)NameFront Connecting SocketBack Connecting Socket (for flush mounting)Watertight CoverP2CF-08P3G-08Y92A-48NModel Temperature RangesInputThermocoupleK (CA)Chromel vs. alumelRange°C°FSetting0 to 39932 to 7991°C/°F0 to 99932 to 9991°C/°FJ (IC)Iron vs. constantan0 to 39932 to 99932 to 7991°C/°FPlatinum resistancethermometerJPt1000 to 99.932 to 1990.1°C/1°F1元器件交易网www.cecb2b.comE5C4E5C4Specifications RatingsSupply voltageOperating voltage rangePower consumptionInputControl modeSetting methodIndication methodControl output100/110, 200/220, 110/120, 220/240 VAC, 50/60 Hz90% to 110% of rated supply voltageApprox. 2 VAThermocouple (with sensor burnout detection circuit) or platinum resistance thermometerON/OFF or P controlDigital settingDigital indicationRelay output:SPDT, 3 A at 250 VAC, resistive load (switching capacity: 330 VA)Voltage output for SSR:10 mA at 5 VDC (with short-circuit protection)H: 5±1 V; L: 0.5 V max. CharacteristicsSetting accuracyIndication accuracyIndication rangeHysteresisProportional bandProportional periodReset range (see note 1)Insulation resistanceDielectric strengthVibration resistanceShock resistanceLife expectancyAmbient temperatureAmbient humidityEnclosure ratingsWeightNote:±2% FS max.±2% FS max.Within set temperature rangeApprox. 0.2% FS (fixed)3% FS (fixed)Relay output:Voltage output:Approx. 20 sApprox. 2 s±1.5% FS min. (variable)20 MΩ min. (at 500 VDC)2,000 VAC, 50/60 Hz for 1 min between charged terminals and uncharged metallic partsMalfunction:10 to 55 Hz, 0.3-mm double amplitude for 10 min each in X, Y, and Z directionsDestruction:16.7 Hz, 4-mm double amplitude for 2 hrs each in X, Y, and Z directionsMalfunction:147 m/s2 (15G), 3 times each in 6 directionsDestruction:294 m/s2 (30G), 3 times each in 6 directionsMechanical:10,000,000 operations min.Electrical:100,000 operations min. (3 A at 110 VAC, resistive load)Operating:Operating:–10°C to 55°C (with no icing)45% to 85%Front panel:IEC standard IP40 (see note 2)Terminals:IEC standard IP00Approx. 200 g (with flush-mounting adapter)1.The reset adjuster of any E5C4 model with ON/OFF control is used to correct any error of the set temperature that is displayed sothat the displayed temperature will coincide with the temperature that has been preset. The reset shaft of any E5C4 is used to resetthe E5C4 model with proportional control.2.The model number of the special watertight cover conforming to IP66, NEMA4 is Y92A-48N.2元器件交易网www.cecb2b.comE5C4E5C4NomenclatureTemperature indicatorOperation indicatorDigital switch fortemperature settingRESET shaftNegative Value Display (Example: –18°C)Overflow DisplayThe following will be displayed if the sensor burnout detection circuitoperates or the process value exceeds the temperature range thathas been preset.(Except models with a set temperature range from 0°C to 399°C,32°F to 799°F and 32°F to 199°F.)Indicates that the temperatureis below 0°C.Note:The E5C4 does not have a parameter display any tempera-ture below 0°C. Therefore, the accuracy of any tempera-ture below 0° displayed by the E5C4 cannot be guaranteed.0°C to 999°C or 0°C to 99.9°Cor 32°F to 999°F0°C to 399°C32°F to 799°F32°F to 199°FOperation IndicatorIndicatorRedLitNot litONOFFOutput3元器件交易网www.cecb2b.comE5C4E5C4DimensionsNote:All units are in millimeters unless otherwise indicated.Terminal Arrangement(Bottom View)48 x 4844.8 x 44.8Dimensions with Flush-mounting Adapter (Accessory),and Back Connecting Socket (Sold Separately)Panel CutoutFlush-mountingadapterPanelY92F-30 Flush-mounting adapterP3G-08 Backconnecting socket60 min.60 min.Tightening screw(96) (see note)Note:109 mm for US08 Back Connecting SocketSide-by-side Mountingof N ControllersNL293+1 03456+1+1141+1237+1 0189 0 0285 0Note:1.Recommended panel thickness is 1 to 4 mm.2.Close side-by-side mounting is possible (in a single direction).Accessories (Order Separately)P2CF-08 Front Connecting SocketTerminal Arrangement/Internal Connections(Top View)Mounting HolesEight, M3.5 x 7.5 semsTwo, 4.5 dia. or Two, M470 max.Two,4.5-dia.holesNote:50 max.20 max.Can also bemounted to aDIN track.4元器件交易网www.cecb2b.comE5C4P3G-08 Back Connecting Socket (for Flush Mounting)27 dia.Installation ConnectionsInputConnect a thermocouple or platinum resistance thermometer to theE5C4 as shown in the following illustration.Voltage output (Terminal 6 isan NC terminal)Platinum resistancethermometer inputRelay outputThermocouple inputSupply voltage100/110, 200/220,110/120, 220/240 VAC,50/60 HzOutputIf the load circuit is a heating control system, be sure to connect theload to terminals 4 and 5. If the load circuit is a cooling control sys-tem, be sure to connect the load to terminals 4 and 6. If the heatingcontrol system is connected to terminals 4 and 6 or the cooling con-trol system is connected to terminals 4 and 5, the temperature of theheating control system or cooling control system will be abnormaland a serious accident may result.If the E5C4 is in frequent operation, such as proportional operation,add an appropriate external relay to the E5C4 by considering the ca-pacity of the load and the life of the relay.Do not ground the output of any E5C4 that has voltage output, other-wise the process temperature may not be accurate.Power SupplyIf a single power supply is used for the E5C4 and the load, the supplyvoltage of the power supply may vary greatly when the load is openor closed if the capacity of the power supply is not large enough.Make sure that the capacity of the power supply is large enough sothat the supply voltage range will be always from 90% to 110% of therated supply voltage.The E5C4 operates at either 50 or 60 Hz.E5C4Terminal Arrangement/Internal Connections(Bottom View)5元器件交易网www.cecb2b.comE5C4PrecautionsMountingTrack Mounting (E5C4 with P2CF-08)When mounting two or more E5C4 models with track-mountingsockets, leave a space of approximately 20 mm on both sides of thesockets where hooks are located.HookDuctP2CF-08PanelFlush MountingInsert E5C4 into the square hole of the panel and insert an adapterfrom the back so that there will be no space between E5C4 and thepanel. Then, secure the E5C4 with a screw.Tightening screwThe P3G-08 can be wired in the same way as the P2CF-08.6E5C4DismountingIf flush mounted, loosen the screw of the adapter and disengage thehooks for dismounting.Temperature SettingThe leftmost digit of any E5C4 that has a set temperature rangefrom 0°C to 399°C will increase by 1 within a range of 0 to 3 eachtime the push button for the leftmost digit is pressed. The leftmostdigit indicating 3 will change to 0 when the push button is pressed.OthersDo not remove the housing of the E5C4, otherwise the housing maybreak.To clean the surface of the E5C4, use a soft cloth wet with neutraldetergent or alcohol. Do not use any organic solvent, such as paintthinner or benzine, strong acid or strong alkali to clean the surface ofthe E5C4, otherwise the surface of the E5C4 will become damaged.元器件交易网www.cecb2b.comE5C4E5C47元器件交易网www.cecb2b.comE5C4E5C4ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.Cat. No. H82-E1-1In the interest of product improvement, specifications are subject to change without notice.OMRON CorporationSystems Components Division 28th Fl., Crystal Tower Bldg.1-2-27, Shiromi, Chuo-ku,Osaka 540 JapanPhone: 06-949-6012 Fax: 06-949-6021Printed in Japan0496-1M (0496) a8